Materials:CGT Extensive Layered Vegetated Roof System

Jump to: navigation, search

Materials:CGT Extensive Layered Vegetated Roof System

Revision as of 17:18, 17 June 2026 by James Klassen (talk | contribs)



Division C - Accepted Materials
Group - Vegetated Roof Systems


CGT Extensive Layered Vegetated Roof System
by Columbia Green Technologies LLC

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
https://columbia-green.com/
Accepted for the RoofStar Guarantee Program
June 11, 2026
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
The Columbia Green Technologies (CGT) Extensive Layered System is a lightweight built-up vegetated roof system that accommodates a variety of layouts. The system’s layers can be easily shaped to fit curves and angles.
This system is designed by CGT to enhance stormwater management by capturing rainwater and irrigation, which can reduce or eliminating runoff. It is specifically engineered to promote healthy plant root development by ensuring adequate airflow throughout the system.
Due to the limited depth of the growing media, Extensive Layered Systems are typically planted with low-growing sedum varieties well-suited for rooftop environments. Growing media depths are determined by structural considerations, plant selection, and stormwater retention objectives.


Extensive VR System (banner).JPG
Manufacturer online resources
CGT Layered Extensive System
System Type
Extensive
System Depth
110 mm (4.38") to 240 mm (9.38")
Growing Media Depth
80 mm (3") to 200 mm (8")
Vegetation Profile
Sedum-Herbaceus-Grasses
Suitable climate zones
All BC zones, subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
Roof Assembly by roofing Contractor

Guarantor's Notes
Systems labeled "Inverted" are designed for a protected membrane roof assembly, also known as an inverted roof assembly.
While Semi-intensive and Intensive vegetated roof systems are limited to only protected membrane roofs (See the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs. To request a written Variance to the published limitation, follow the requirements in Article 1.1.3.6..
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home